• Here is a link to the full explanation: https://rollitup.org/t/welcome-back-did-you-try-turning-it-off-and-on-again.1104810/

Search results

  1. SnapsProvolone

    Extracting 2200 CF

    Sentinel makes a great setup. If you have natural gas or propane a co2 generator is the way to go. If no fuel source is available your stuck hauling co2 tanks for refills. :( Use a fuzzy logic controller on a tank. Venting would blow your air conditioning and co2 out of the room. :( With...
  2. SnapsProvolone

    Extracting 2200 CF

    If you plan to run a minisplit, you could run a co2 generator/controller and a good dehumidifier then forget extraction with fans.
  3. SnapsProvolone

    $5k SCFE Vessels

    Im all ears. Lets see it in action!
  4. SnapsProvolone

    National Drug test day

    Im testing some drugs as we speak.
  5. SnapsProvolone

    Temporary solutions for high heat areas

    Swamp coolers add humidity. Not good. Buy an air conditioner.
  6. SnapsProvolone

    Schuylaar's Easter Weekend Sesh - Wal-Mart Workers Costs Taxpayers $2B

    People in this country are a bit spoiled. Look at countries like India and China, that was our workplace 100 years ago. We insulated ourselves from reality with cost increasing osha regulations and insurances.. Now we want cheap products but our safebwell regulated workplaces cant provide...
  7. SnapsProvolone

    New Grow w/Co2 Addition

    Use of a co2 controller is recommended. If your venting you need an environmental controller as well so you can disable co2 enrichment when exhaust fan is running. If using a tank you want a fuzzy logic controller. From the sounds of things you need to deal with heat with constant exhaust...
  8. SnapsProvolone

    Water cooling system for a grow box, well.. sort of..

    Anyone ever drop water cooled heatsinks directly on a LED array so as to remove the heat before it warms the air?
  9. SnapsProvolone

    Confused about the growing laws

    Yodaweed - They havent gone so far as to make an exact distinction about the definition of mature. The intent is that only three plants would be flowering at one time. The industry regards this to mean plants in a room lit 18 ormore daily. Presexing is not regarded as flowering. The grey...
  10. SnapsProvolone

    Yields from 4×8 flood and drain?

    2kW, 4x8, co2, can easily make 3 - 4 pounds with a SoG and a worthy strain. Could do under 2 lbs without co2 and/or a low yield strain.
  11. SnapsProvolone

    CO2 in a tent

    You would still have heat and humidity to deal with.
  12. SnapsProvolone

    Grow tents in tandem in garage. How many BTU mini split?

    If your using cooltubes be aware that the makeup air will need to be conditioned unless it's within tolerance.
  13. SnapsProvolone

    Grow tents in tandem in garage. How many BTU mini split?

    In addition to a basic J manual calculation one should add 3.414 btu/hr for each watt used in the room.
  14. SnapsProvolone

    Do not blast on crappy Sillicone

    Make silicone gummy bear edibles. Lol
  15. SnapsProvolone

    Straining in freezer?

    Sounds like a syringe filter or vacuum assisted filter is required. One could very carefully use a syringe to gently siphon off the solvent leaving the precipitate layer and a little good solvent.
  16. SnapsProvolone

    mogul to medium connectors

    http://www.amazon.com/Satco-92-414-Medium-Enlarger-Extension/dp/B000V5347A/ref=sr_1_1/188-9919775-1524708?ie=UTF8&qid=1397675606&sr=8-1&keywords=medium+to+mogul+adapter
  17. SnapsProvolone

    mogul to medium connectors

    Yes they make em. Mogul to medium base adapter. Search google for "mogul medium adapter"
  18. SnapsProvolone

    Clone Room Question...

    You can try a 15/15 but i think the on period is excessive.
  19. SnapsProvolone

    ELECTRICITY!!!

    Anything under 3 or 4 kW of light shouldnt arouse any attention provided no other clues give you away. Running on a flip makes it diifficult for smartmeters to detect a 12/12 usage pattern.
Top