Moflow
Well-Known Member
Correct. 2 x citizens, 1212s. 3500K Current 700mA Volt 33.9 power 23 wattsWondering if you guys can help me out? Making a small cob unit for my aquarium and want to run 2 cobs on it. Citi 1212 clu048. Would an hlg-60h-c700 be a good choice?
I'd like to keep it under 100wand it doesn't need a very strong current, I'm not growing cannabis with it just keeping my aquarium plants happy.
Will that work for what I want? And that will put me around 70w total correct?
Hlg 60h c700 v range is 50v - 100v.
2 x 33.9 v = 67.8v. Which fits into the min max range of that driver for a total of 56 watts.