  1. B

    Humidity issues (can’t get it up ) DIY ultrasonic fogger

    Hey RIU… so after a constant battle the last couple of weeks, I’m here for some help and advice. As always it’s much appreciated… Where I’m at it’s cold and very dry out. Im having a hard time keeping my tents humidity higher than MAYBE 35-40% while running a small humidifier 24/7 in the room...
  2. B

    2 tents 1 fan…

    Hi everyone.. like the title says, I’m trying to see if I can run (1) fan to exhaust (2), small-ish tents. Tent 1 is 32x60x80 (almost 5x3) and the other is 24x48x60. Based on my beautiful sketch, does this seem like it would work? Here’s some details; 5x3 has a Viparspectra 480w LED...
  3. B

    5’ x 30” area pot sizing..

    High everyone.. I know this question is probably beaten to death around here but I’m reading and reading and still can’t decide what route I want to go.. I have a variety of strains that I’d like to be able to have a good bit of each after harvesting to use until next fall/winter.. There are 6...
  4. B

    LED setup for 4x4

    I am looking to start a small 4x4 tent up using Viparspectra XS series lights. Is 4 - XS2000 (rated at 240w each) going to be overkill?
  5. B

    RF Interference from In-line Exhaust fan?!

    so I’ve read that RF interference can be picked up via AM radio through digi ballasts.. is this a known issue for exhaust fans as well? I have a Terrabloom 8” fan with a speed controller that I think is causing interference but I don’t know the magnitude of it or weather or not it’s an issue...
  6. B

    Scrubbing inside of a room..

    So if you scrub the air inside the room, what would the general rule of thumb be? Ex if I have a 6” fan pulling 400cfm out of the room with a CF.. what size filter/fan combo would be needed inside the room to prescrub as secondary measure? Would a 4 inch work?
  7. B

    Should I over OVER size my exhaust fan?

    The space I plan on using is only about 112 cubic feet. A 6 inch 350-400 cfm fan should easily do the job for this size area and scrub with no problem but I’d like to prepare for the worst.. an 8 inch fan basically costs the same as a 6” (difference of $9 between Vortex S600 and S800).. would...
  8. B

    Exhausting to outside in a basement.. ?

    If you had a 400cfm exhaust inside of a built closet in a basement exhausting directly outside the house and had a passive intake, could draft from the chimney be pulled and cause the gas boiler spill switch to trip or even worse potentially pull CO into the basement through a backdraft? I may...
  9. B

    Exhaust / Carbon Filter question, need advice...

    Hey everyone, let me try to explain a little. I’m in the process of designing a room within my basement.. dimensions are 4’ wide, 6’ deep and 7’ high (or 168 cubic feet).. I’m looking at the AC Infinity Cloudline S6 fan rated at 347CFM for exhaust pulling through a Can-lite 6” carbon scrubber...