Search results

  1. H

    New Electrical Panel? Setup of a new warehouse setup, PLEASE HELP!

    Send an email to [email protected], they can help you. The 70A maybe a 480V or 600V feeder which goes to a stepdown transformer for 120/240, is your place single or three-phase.
  2. H

    Light controller relay out, new controller now breaker trips after getting hot...

    Is the 50A two-pole breaker getting hot, could be faulty breaker, I would pull the breaker and check the bus, it may be oxidized. Is it a Federal Pioneer breaker.
  3. H

    Short cycle timers... burning them out in a day

    Get a PLC and you can have 100s of time cycles even down to 1/100 second. Send an email to [email protected], they can help.
  4. H

    Total Hydroponic Control (T.H.C.) - The build starts NOW!

    I built an automated reservoir cleaner. Used a 2HP pump and 4 oscillating ratcheting sprinkler heads attached 6" apart on a column from the top of the pump. The unit was dropped through the top of a 250G square reservoir. About 4" to 6" of water and cleansing solution was put int the bottom...
  5. H

    MMPR Grow op: Small Scale

    You heard wrong, everyone was laid off at medijean, only ones left there are jean and his wife and a coule flunkies to help grow under his MMAR.
  6. H

    MMPR Grow op: Small Scale

    I don`t hide behind anonymity, I know two people who worked there, one of them was my sister, she was sexually harrassed by Jean, then she was fired by Jean's wife Beverly after she found out. All that matters is that they will not be getting an LP.
  7. H

    MMPR Grow op: Small Scale

    There was never any legal documents signed, that place was a gong show, esecially when Jean was screwing the receptionist, paying her rent, and buying her a car, all with funds allocated for the facility.
  8. H

    MMPR Grow op: Small Scale

    I don't how you can steal your own genetics.
  9. H

    MMPR Grow op: Small Scale

    MediJean is MediGone lol, their master grower is now suing them in Vancouver Supreme Court for $500K. They fired him and then kept all of his genetics. Medijean is a joke, I know a few people who worked there and no way snowball's chance in hell with they ever get a license. Only thing going on...
  10. H

    Total Hydroponic Control (T.H.C.) - The build starts NOW!

    SIEMENS Logo or Simatic are good choices for PLCs.
  11. H

    Newest Setup! 1 of 4 rooms

    The PLC control for all your lighting is smart. Did you program the PLCs to have all your sensors linked to it.
  12. H

    Thermostat control unit

    Ranco makes a two stage controller, ETC211000, I've installed over a 100 of them and they work great. One stage for AC unit and second stage for venting.
  13. H

    Thermostat control unit

    Titan is crap, get a Ranco etc111000 and a receptacle to plug in your device, you can extend the probe with some 2 conductor 20awg wire. Johnson controls is a good choice, a bit tricky to set, Ranco is easier to program.
  14. H

    Custom Electrical, HVAC, and Irrigation

    My 25 years experience encompasses electrical, irrigation, HVAC, CO2 implementation, environmental controls, automation, power generation, security/fire alarms, CCTV, construction, racking systems, motorized systems, radio/remote systems, and much more. I am an electrician but also worked as an...
  15. H

    Approved LP List (Updated)

    Medijean is Medi gone lol.
  16. H

    Wiring a lighting controller

    When the contactors buzz, they need to be cleaned, tiny parcles, especially metal particles get trapped when the coil is energized.
  17. H

    Wiring a lighting controller

    What a piece of junk. Using the quick-wire connection on the back of the receptacles is plain lazy, should have used ring or spade terminals and connect to the screw terminals on the receptacles. The ring terminals and quick connect terminals should have been connected to the wires with ratchet...