8x1000 watts CO2 Hydro grow Jacks Back

JACKMAYOFFER

Well-Known Member
Jack,are you using a cool coil in your reservoir ?Is it piped to the chiller running your Ice boxes?
No running a pump from my 60 gallom rez to the chiller from the chiller out to 3/4" line tapped off to the ice boxes then back to the rez....:blsmoke:
 

tilemaster

Well-Known Member
U better be sorry Gambler:eyesmoke:


Sorry if i didn't get ur name in the CREDITS this time around... went back in my journal as far as i could, but ran out of space.

We now r3turn u 2 JACKMAYOFFER's JOURNAL.[/QUOTE]
 

JACKMAYOFFER

Well-Known Member
Here is a picture of the chiller and rez and my new moms..Re did my mom room and replaced my moms Here is my new moms... Raskal OG KUSH,LA WOMAN,MASTER X BUBBA KUSH,SFV KUSH,JULIAS CEASER KUSH,TAHOE OG KUSH,LARRY OG KUSH, And I also obtained some beans from the JOESHMOE auction at THC bay Joe was busted and The bay had a auction to help his family Here is a list of the beans these will be added to my moms some real gems...of some amazing beans this is what I won These will also become my moms..BUBBA KUSH X DEEP CHUNCK,CHEMDAWG #4 X DEEP CHUNCK, CHEM DAWG #2 X DEEP CHUNCK, DIESEL KUSH,BLOCK HEAD XNL X LEAPORD KUSH X PURE KUSH, WHITE X STAR DOG...
 

Attachments

DaGambler

Well-Known Member
looks like some Botanicare fittings in that ebb 'n flow tray. they make some solid azz fittings. much better than a different brand that i also tried.
.
 

dagobaker

Well-Known Member
Here is a picture of the chiller and rez and my new moms..Re did my mom room and replaced my moms Here is my new moms... Raskal OG KUSH,LA WOMAN,MASTER X BUBBA KUSH,SFV KUSH,JULIAS CEASER KUSH,TAHOE OG KUSH,LARRY OG KUSH, And I also obtained some beans from the JOESHMOE auction at THC bay Joe was busted and The bay had a auction to help his family Here is a list of the beans these will be added to my moms some real gems...of some amazing beans this is what I won These will also become my moms..BUBBA KUSH X DEEP CHUNCK,CHEMDAWG #4 X DEEP CHUNCK, CHEM DAWG #2 X DEEP CHUNCK, DIESEL KUSH,BLOCK HEAD XNL X LEAPORD KUSH X PURE KUSH, WHITE X STAR DOG...
how much for the chiller?......what size.....what size is the pump attatchment..... 1/2 inch or 3/4 inch....and how did u have to hook it up electrically?
 

JACKMAYOFFER

Well-Known Member
how much for the chiller?......what size.....what size is the pump attatchment..... 1/2 inch or 3/4 inch....and how did u have to hook it up electrically?
Chiller is a 2 hp and thats under rated most of the chillers out there are way over rated The chill kings are commercial chillers I tried my 1 hp chiller and I could not get the temps lower then 67 deg with the chill king I can get my rez temps in the 40's :mrgreen: As far as price I get them at cost ..I think they retail for $2,000 there not cheap but this allows me to add many more lights and still be abel to cool them. The pump is 1/2 hp sits in the bottom of the rez plumbed in to a 3/4 hose from 3/4 hose to a barb mounted to 3/4 pvc..
 

BooMeR242

Well-Known Member
i dont want to sound dumb but im new to the indoor and hydro game still leanrin bout it for my grow but wats the chiller for? the rez and water./nutes? or how does it keep the room cooler. noob question im sure but sum clarity would be nice :) thanks lol
 

JACKMAYOFFER

Well-Known Member
i dont want to sound dumb but im new to the indoor and hydro game still leanrin bout it for my grow but wats the chiller for? the rez and water./nutes? or how does it keep the room cooler. noob question im sure but sum clarity would be nice :) thanks lol
A chiller is a must for hydro it is normally used to cool the water tep in the rez ideal is 65 to 68 deg.This allows maximum uptake of nutrince to the roots more oxygon...Then there is the hydro inovation stuff it uses clod water cooled by a large chiller the ice boxes/Condensor coil sit between the lights the boxes cool the air and there is virtually no heat coming from the light this drops temps in the room also allowing the lights to be placed rite on top of the plants for maximum lumens. You can also use the cold air blowing through the lights to cool your room..If you go to the pics in my first page you can see the ice boxes between each light.. My water temp is 50 deg going into the ice boxes and the air going through the lights is in the 60 deg range:mrgreen:..I have complete control over the room temp ,water/ nutes, co2 and lumens I am god in the room..
 

BooMeR242

Well-Known Member
haha god u are... makes sense def sounds worth the investment to keep temps in control cuz ive been lookin at buyin a 24,000 btu AC unit the one with a seperate copper wire run etc. i like the fact u keep the light temps down and closer to the canopy for max lumens since ure paying for it. thnx jack!
 

DaGambler

Well-Known Member
...I have complete control over the room temp ,water/ nutes, co2 and lumens I am god in the room..
ur only god until you screw up a crop ... keep growing long enuff and it will happen :twisted: :eyesmoke:

pH, ppm, bugs, mold, drying techniques ... plenty of room for human error.
.
 

Dr. VonDank

Active Member
JACKMAYOFFER-

Great set-up!!!----I love the Hydrogen Inov. products and the owner is a stand up guy. I have ran many room set-ups with the hydrogen co2 generators. I see allot of growers running dehumidification units, A/C plus chillers. Trying to get their room temps down, lowering their humidity while still being able to utilize co2. The chillers give-off a good amount of heat as well as the A/C unit and dehumidifiers. Your flowering room looks about 1000---1200 cu ft???(should be close). I also noticed you have your digi's in the room as well. I think you have a beautiful room built there brother but If your interested I could give you a few simple changes that would save you about 20 to 30amps of use while still maintaining the yields you are getting now. PM me if you want to hear my thoughts... Very clean layout--looking forward to following the grow...
 

JACKMAYOFFER

Well-Known Member
ur only god until you screw up a crop ... keep growing long enuff and it will happen :twisted: :eyesmoke:
.
I was batting a 1000 until I threw the clones in the new room and put them into light shock ..:roll: I have learned my lesson and it is all part of the learning curve ..I dimmed the lights to 50 % and cut half off .I fed them some revive from Advance and they are now doing much much better I have turned the lights back on and the growth has taken off... This has set me back a couple weeks.. I almost pulled all them and started over but figured it would be a good time to see what it takes to revive a clone that was almost dead ..Its amazing what this plant can go through...:mrgreen: And Degambler it all depends on what your deffenition of god is ..:twisted::mrgreen:
 

JACKMAYOFFER

Well-Known Member
JACKMAYOFFER-

Great set-up!!!----I love the Hydrogen Inov. products and the owner is a stand up guy. I have ran many room set-ups with the hydrogen co2 generators. I see allot of growers running dehumidification units, A/C plus chillers. Trying to get their room temps down, lowering their humidity while still being able to utilize co2. The chillers give-off a good amount of heat as well as the A/C unit and dehumidifiers. Your flowering room looks about 1000---1200 cu ft???(should be close). I also noticed you have your digi's in the room as well. I think you have a beautiful room built there brother but If your interested I could give you a few simple changes that would save you about 20 to 30amps of use while still maintaining the yields you are getting now. PM me if you want to hear my thoughts... Very clean layout--looking forward to following the grow...
Feel free to tell me what you think..I have been in the electrical game for 14 years now any suggestions would be great...I am always willing to learn something new...Jack:blsmoke: My room is 9' x 15' so your sq footage is a little off...
 
Top