C02 setup for 16x16 room

2com

Well-Known Member
@MrStickyScissors I just read in the other thread you said "
I got 12,000 Btu Emerson cool mini split. 250 pint dehumidifier, 7 gAvitas, number 10 copper wire. Double 40 breaker. And ebb n flow trays.
You may have already run this room and setup and don't need me to be questioning your setup or configuration, so if I'm off base here, my bad. Am I reading right that you have a 16x16 room, with 7 Gavitas (1100watts each, or 750watts each? I don't know much about'em or which ones you have) and "only" 12,000 Btu of ac? Is that gonna be enough cooling for this heat load?
5200W or 7700W of HID lighting (depending), plus the dehumidifier, and other stuff, seems like alot for 12,000 Btu of cooling.

Am I trippin'? It's quite possible, I'm tired as fuck.
@MidnightSun72?
 

MidnightSun72

Well-Known Member
@MrStickyScissors I just read in the other thread you said "

You may have already run this room and setup and don't need me to be questioning your setup or configuration, so if I'm off base here, my bad. Am I reading right that you have a 16x16 room, with 7 Gavitas (1100watts each, or 750watts each? I don't know much about'em or which ones you have) and "only" 12,000 Btu of ac? Is that gonna be enough cooling for this heat load?
5200W or 7700W of HID lighting (depending), plus the dehumidifier, and other stuff, seems like alot for 12,000 Btu of cooling.

Am I trippin'? It's quite possible, I'm tired as fuck.
@MidnightSun72?
You ain't tripping. He'll need around 30-36000 bTU AC to cool that room proper.
 

Milky Weed

Well-Known Member
I have about 10k in
If you got 10k invested, may as well go all out and use proper gas.
I’m running 7 de hps great air circulation
yeah your ac is going to be working HARD. I would not use burners with hps, for sure use gas tanks.

Like LordHooha said, it likely won’t work.

Youll need more mini splits, or scrap the sealed room idea, and set up a big ol outtake fan with some uv light sterilizing on the outtake for smell and just run a non Co2 room.
 
Last edited:

MrStickyScissors

Well-Known Member
If you got 10k invested, may as well go all out and use proper gas.

yeah your ac is going to be working HARD. I would not use burners with hps, for sure use gas tanks.

Like LordHooha said, it likely won’t work.

Youll need more mini splits, or scrap the sealed room idea, and set up a big ol outtake fan with some uv light sterilizing on the outtake for smell and just run a non Co2 room.
I’ll add one more
 

MrStickyScissors

Well-Known Member
If you got 10k invested, may as well go all out and use proper gas.

yeah your ac is going to be working HARD. I would not use burners with hps, for sure use gas tanks.

Like LordHooha said, it likely won’t work.

Youll need more mini splits, or scrap the sealed room idea, and set up a big ol outtake fan with some uv light sterilizing on the outtake for smell and just run a non Co2 room.
It’s a really nice unit if it doesn’t cool it I’ll simply buy another one
 

MidnightSun72

Well-Known Member
Lighting alone is over the cooling he has currently. He's setup for failure it looks like.
I didn't notice the carpet. Thought it was concrete.
It’s a really nice unit if it doesn’t cool it I’ll simply buy another one
you will need another 2 if you are buying that same model. For each watt you spend in your room you need 3.41BTU of cooling. This include the watts of any fans, pumps, lights, dehumidifiers etc.
 

Lordhooha

Well-Known Member
Stop hating
Dude no hate there's literally no reason for me to.hate on your little grow man. I was just letting you know.i have 25 tons of cooling per room for 6 rooms and 5 for the others. I had 2 36k that were just finished getting installed for my drying room.
 

Lordhooha

Well-Known Member
I didn't notice the carpet. Thought it was concrete.

you will need another 2 if you are buying that same model. For each watt you spend in your room you need 3.41BTU of cooling. This include the watts of any fans, pumps, lights, dehumidifiers etc.
yah i seen it and was like thats how you get sick right there or ruin some shit.
 

MrStickyScissors

Well-Known Member
Dude no hate there's literally no reason for me to.hate on your little grow man. I was just letting you know.i have 25 tons of cooling per room for 6 rooms and 5 for the others. I had 2 36k that were just finished getting installed for my drying room.
Came across that way, I don’t care how small or big someone’s grow is I still show love. To each their own
 

MrStickyScissors

Well-Known Member
Dude no hate there's literally no reason for me to.hate on your little grow man. I was just letting you know.i have 25 tons of cooling per room for 6 rooms and 5 for the others. I had 2 36k that were just finished getting installed for my drying room.
Then I’ll buy 5 more a/c ‍♂Thanks for pointing that out for me tho
 