they are good guides. most are reasonably accurate for scaling purposes. i provided one example where one manufacturer's simulator was broken, to satisfy your request.
i can post some observatons of temperature effect with cobs. im not interested in current time at getting exact par/lumen output from any cob as for my purposes its not justified to have a calibrated chain of light sources from nist to me. maybe down the road when i get a bigger sphere to test fixtures
right now i am only interested in relative differences between cobs and can say with fair certainty in multiple tests that veroC isnt a magic bullet, it is essentially identical to a citi 1825 gen 5 at all currents from 0.1 to 3.6A. The test data literally falls right on top of each other.
theyve long since paid for themselves. youre in the gravy zone now