newuserlol
Well-Known Member
Limited space, go vertical. Bigger canopy less footprint required.
he may be a little oldman lmao but imc there you are talking to a pro.
Limited space, go vertical. Bigger canopy less footprint required.
aye lad, the boys from the Boutique will have a stall. If any of you cats happen to be in town just gives a shout, we normally have plenty passes.I was very tempted having followed your grow. Space was never a friend of mine. Damned cupboard. Soon. Soon.
Are you guys getting a stand at the cup this year? Would be good to stop by with the missus and say hello.
right gonna ask a few questions................well I sed I was going to have 2 5 inch hoods rite.......so shld I connect a 6 inch fan to those......and do I have my filter connected to it aswell so it pulls air thru my filter thru the hoods and out the room?...or shld I have my filters on a sep fan?.....so like 1 fan running the hoods and a nother running the filters?
The best environment would be from 1 fan for hoods and 1 for filter, the fan cooling the hoods would shift more air without having to suck through a filter first.
got quite bit of space in me room....im using open lights aint liking the temps......so im getting the hoods I was asking how to rig it up..........do I connect the filter to the hoods and pull it thru it on 1 fan or have a sep fan for filters.......dose sucking the air thru the hoods work betta than blowing the air thru it......
The best environment would be from 1 fan for hoods and 1 for filter, the fan cooling the hoods would shift more air without having to suck through a filter first.
how does that work then if the fan on hoods isnt on a filter? would it not then vent out unfiltered smelly air? and would make having a filter in the 1st place pointless?
yer that's what I was thinking of doing......cos I want to keep tems below 30 even in summer...........ok so with the fan on the hoods do I have the fan blowing thru or sucking?.....forwards or backwards
soz about shitty pic but sommert like this?.....View attachment 2805984
Yeah, if you can get the hood ducting to go straight through with no bends it would be ideal but that's good to go if you Move the hood fan to the same place but at the other end.
Have it pulling instead of pushing.
If you have a tent they have vent holes at both sides and on the roof, you can blow fresh air from the room the tent is in straight through the hoods and out the other side, this air never enters the tent so stays clean at all times.
Then you would pull the supply air through a filter and plain duct out the other duct exiting through the roof.
If you have a sealed room then buy a hole saw kit and set up as described.
Yeah, if you can get the hood ducting to go straight through with no bends it would be ideal but that's good to go if you move the hood fan to the same place but at the other end.
Have it pulling instead of pushing.
yer just turn the fan around....
and u rec a 5 or 6 inch fan for the hoods yorky......they will be 5 inch hoods........there will be 2 600 in there want to try me best to below 30 c
a 5'' will not cool 1200 hps u need at least a high power 6'' a 8'' would be better.
a 5'' will not cool 1200 hps u need at least a high power 6'' a 8'' would be better.