not horrible but definitely work on lowering those temps
your humidity is fine, could raise it a some if you wanted
shoot for max 80 F min 60 F
if in flowering that humidity is fine, but if you are talking seedlings you want about 70%...and have it lower over the vegetative cycle![]()
swap the out take with the intake, so the 400 cfm sucking out and the 180 in, this will give you the negative presure as well as cooling your room more.
Did i just read that twice.? wtf
swap the out take with the intake, so the 400 cfm sucking out and the 180 in, this will give you the negative presure as well as cooling your room more.
I did have it that way. the 400 cfm one was hooked up to the carbon filter and then going threw the light hood and the 188 cfm pulling in air. so i should put it back the way i had it? it stayed the same temp after i switched them![]()
its easier to pull air than to push it, so to achieve the full 400 cfm you need to have the fan at the last possible duct spot before exciting the grow room. so your air flow should go into box through passive intake, then be sucked in through the carbon filter at the top of your box, then go through your cooled light, then go through your fan, then go out of your box. so you always want the fan pulling air for as much time as it can. if you had it set up to go through thre fan, then light, then carnbon filter, youd loose alot of your rated CFMS
swap the out take with the intake, so the 400 cfm sucking out and the 180 in, this will give you the negative presure as well as cooling your room more.