PotPower
Active Member
Here is a teaser picture of the room I am currently putting together.
All in the floor crawl space ventilation and 4000w of hanging lights ready for ducting and power!
I am using these parts. and have everything venting through the floor/crawlspace to the rear of the house then exhausted.**This is a caregivers set up and is legal**
Powerbox DCP-1500 60amp power module
CAP Fuzzy c02 room controller to trigger the power box.
20 gallon Co2 tank
4 radiant 1000w HPS hortilux bulbs
Light track 9' with 2 light movers.
Air cooling of all lighting 430+ cfm cage fan pushing air/4" inline booster fans for drawing air through from exhaust end.
13000 BTU portable Air conditioner
power run with 4ga wire from main 100amp breaker to sub panel.
Sub panel 70amp GFCI breaker to power box
30amp GFCI breaker to 2 outlets for misc, power
10' inline 730+cfm fan for exhaust
2x 39 gallon reservoir for nutrients and water.
65 x 5 gallon pots and drip trays
Sunshine #4 10 bags *expensive*!
Current room condition day or night is a steady 70 degrees with no ventilation.
50% completed and I will keep people updated.I am putting 2 of the lights on tracks and 2 will be stationary.
All lights will be air cooled and sealed bringing in cool air from the crawl space then exhausted through insulated ducting outside of the house.
Main room exhaust is pulled through a 10' 730+cfm can fan and about 25' of insulated exhaust ducting.
Portable air conditioning unit 13,000 BTU with 6' external hosing ducted the same, intake from crawlspace exhausted through insulated ducting also.
I have run 4gauge 3 wire with ground through insulated waterproof conduit into a sub panel. About 60' ft and i will be using about 5000w or less total through a sweet powerbox 1500 60amp GFCI unit i decided to splurge on. more updates to come
All in the floor crawl space ventilation and 4000w of hanging lights ready for ducting and power!
I am using these parts. and have everything venting through the floor/crawlspace to the rear of the house then exhausted.**This is a caregivers set up and is legal**
Powerbox DCP-1500 60amp power module
CAP Fuzzy c02 room controller to trigger the power box.
20 gallon Co2 tank
4 radiant 1000w HPS hortilux bulbs
Light track 9' with 2 light movers.
Air cooling of all lighting 430+ cfm cage fan pushing air/4" inline booster fans for drawing air through from exhaust end.
13000 BTU portable Air conditioner
power run with 4ga wire from main 100amp breaker to sub panel.
Sub panel 70amp GFCI breaker to power box
30amp GFCI breaker to 2 outlets for misc, power
10' inline 730+cfm fan for exhaust
2x 39 gallon reservoir for nutrients and water.
65 x 5 gallon pots and drip trays
Sunshine #4 10 bags *expensive*!
Current room condition day or night is a steady 70 degrees with no ventilation.
50% completed and I will keep people updated.I am putting 2 of the lights on tracks and 2 will be stationary.
All lights will be air cooled and sealed bringing in cool air from the crawl space then exhausted through insulated ducting outside of the house.
Main room exhaust is pulled through a 10' 730+cfm can fan and about 25' of insulated exhaust ducting.
Portable air conditioning unit 13,000 BTU with 6' external hosing ducted the same, intake from crawlspace exhausted through insulated ducting also.
I have run 4gauge 3 wire with ground through insulated waterproof conduit into a sub panel. About 60' ft and i will be using about 5000w or less total through a sweet powerbox 1500 60amp GFCI unit i decided to splurge on. more updates to come
Attachments
-
43.5 KB Views: 68
-
50.5 KB Views: 98