Level 7 security requirement for storage, so much for the little guys getting a licence.
7.1 General
7.1.1 . The following are examples of the minimum requirements which the Bureau will accept for level 7 security. This level is determined by the location of the licensed dealer and the maximum inventory. The monetary value of the inventory is calculated using the illicit value of the drug. (See Appendix B, Table 1) .
7.1.2 . The Bureau will consider alternate forms of secure environs, such as laminates, providing they are equal in force resistance to the examples given below.
7.1.3 . Minimum Electrical Detection Requirements:
Smoke detector inside vault.
Sufficient detectors to indicate when there is an unauthorized attempt to access, penetrate, remove, or open the vault or safe.
Detectors which will indicate when there is an unauthorized opening of the vault or safe door or any attempt to circumvent the detector is made.
All vault and safe alarms on one zone which is separate from other detection devices installed in the warehouse.
Vault or safe alarm equipment is to be monitored by a U.L.C. (Underwriters Laboratories of Canada) approved central monitoring station. When such service is unavailable the Bureau will consider alternates.
Grade "B" Line supervision.
Control boxes for the security system are to be located inside the vault or safe.
Proximity detector (capacitance detector) if used in conjunction with a safe must be placed either inside or underneath the safe whenever feasible.
7.1.4 . All electrical conduit for the alarm system, security equipment, lighting, telephone, etc. shall be in accordance with any applicable electrical code. All conduit entering the walls, ceiling, or floor shall have at least one offset within the vault structure. Arrangement of bends shall be so that drainage is to the exterior. Conduit shall not exceed 3.8 cm (1 1/2") diameter.
7.1.5 . The secure environs if they include a vault, safe or caged area, are to be located at least 1 metre (3') from any outside wall if located on a ground floor or an accessible roof. The Bureau may consider certain conditions to be equivalent to the 1 metre (3') requirements. These conditions may be in the form of another building in close proximity to the secure environs, ditches, cement pylons, etc. The 1 metre (3') requirement applies, regardless of the distance from the ground or accessible roof, if construction is to be against a wall which is common to another company.
7.1.6 . Ventilation - Openings in the vault for ventilation or air conditioning are not allowed if the overall security of the vault is lowered. In instances where either a circulation of air or air conditioning is necessary for the drug stability, one of the following conditions must be met:
Openings must have one dimension 15 cm (6") or less and the total area of the opening cannot exceed 619 cm2 (96in2).
The opening or duct work must be protected by the installation of N 5 (15 mm (5/8")) steel reinforcing rods securely anchored into the wall on 15 cm (6") centers and horizontally reinforced on 40 cm (16") centers, or a grill.
If a grill is to be used it is to be constructed of either N 5 (15 mm (5/8")) steel reinforcing rods on 15 cm (6") centers and horizontally reinforced on 40 cm (16") centers, or 3.5 mm (10 gauge) expanded metal mesh, welded into a 6 mm (1/4") metal frame. The frame is to be securely anchored to the wall.
7.2 Secure Environs (Vault)
7.2.1 . Walls
Cement Block
High density concrete block wall 15 cm (6") thick reinforced every void with N 5 (15 mm (5/8")) deformed steel reinforcing bars. Each void filled with type "M" mortar, or
Poured Concrete (20.7 MPa (3000 lb/in2) minimum).
10 cm (4") poured concrete reinforced every 20 cm (8") with deformed steel reinforcing bars N 5 (15 mm (5/8")) thick in both directions or reinforced using 3.5 mm (10 gauge) expanded metal mesh which has opening 5 x 2.5 cm (2" x 1").
Ceiling/floor
10 cm (4") poured concrete (20.7 MPa (3000 lb/in2) minimum) reinforced with N 5 (15 mm (5/8")) deformed steel reinforcing bars every 20 cm (8") in both directions or reinforced with 3.5 mm (10 gauge) expanded metal mesh which has opening 5 x 2.5 cm (2" x 1").
7.2.2 . Door
Any fire resistant bank type vault door will be acceptable. (Insulated Record Storage Vault Door).
Any inside escape handle attached to the door must be removed or rendered inoperable. A telephone, intercom or other type of warning device may be installed, to replace the escape handle for those instances when someone is accidentally locked inside the vault. These warning devices are not a Bureau requirement.
Combination lock is to be changeable, manipulation proof, possessing at least 3 tumblers and have a spy proof dial.
The lock combination must be stored in a secure location and changed yearly, or whenever a person knowing the combination no longer requires it.
7.3 Safe
7.3.1 . If a safe is to be used for level 7 security instead of a vault, it is to be a burglar resistant safe which is Underwriters Laboratories of Canada (ULC) rated at a level ULC-TL-30.
7.3.2 . The safe is to be located in a caged area which meets the requirements described in Appendix D.
7.3.3 . The caged area described in 7.3.2 should be located in a locked room.
7.3.4 . Safe must be anchored to the floor in such a manner that it cannot be removed without first opening the safe door.
7.3.5 . If the safe is equipped with a combination lock, the lock combination must be stored in a secure location and changed yearly, or whenever a person knowing the combination no longer requires it.