Hello,
I am about to finish my aero system and I would like to know if the PVC piping size looks OK before I glue everything together.
I have 39 sprayers (160l/h / 4.2gl/h) which equal 6240l/h or 1642gl/h in total. I have a 6500l/h main pump which will feed the sprayers and a 3000l/h secondary pump which will pump the nutrient solution back to the reservoir.
To keep reservoir temperatures cool (no budget for a water chiller atm) I decided on relocating it to another room. The distance from the reservoir to the manifold will be 5m.
I have a 1" pvc pipe for the manifold, then six 1/2" pvc distribution pipes (max. 7 sprayers per tube) and 1/4" tubing for the sprayers.
The manifold (I.D. ~27mm) will be mounted on top of the tray for top feed sprayers and will be connected to a 1" garden hose (I.D. ~25mm).
Do you think this will work out or do I need larger or smaller diameter tubing for the manifold or the distribution tubes?
Also does the garden hose seem to have the right size?
I am about to finish my aero system and I would like to know if the PVC piping size looks OK before I glue everything together.
I have 39 sprayers (160l/h / 4.2gl/h) which equal 6240l/h or 1642gl/h in total. I have a 6500l/h main pump which will feed the sprayers and a 3000l/h secondary pump which will pump the nutrient solution back to the reservoir.
To keep reservoir temperatures cool (no budget for a water chiller atm) I decided on relocating it to another room. The distance from the reservoir to the manifold will be 5m.
I have a 1" pvc pipe for the manifold, then six 1/2" pvc distribution pipes (max. 7 sprayers per tube) and 1/4" tubing for the sprayers.
The manifold (I.D. ~27mm) will be mounted on top of the tray for top feed sprayers and will be connected to a 1" garden hose (I.D. ~25mm).
Do you think this will work out or do I need larger or smaller diameter tubing for the manifold or the distribution tubes?
Also does the garden hose seem to have the right size?
Attachments
-
25.9 KB Views: 33