yes you have to be in parallel, no i dont think it needs to be equal load per pair of leads. in fact it might be bad to gang both + leads together, no reason i can see to do that
id do it like this if you want to balance (might be cumbersome if you dont want wiring between bars but youd need to find 6-slot wagos for that (or use marine busbars or the 8-slot non reusable ideal push-in terminals):
wago#1
1 + from driver output#1
2 to cob A +
3 to cob B +
4 to cob C+
5 to wago #2
wago #2
1 + from wago #1
2 to cob D +
3 to cob E +
4 to cob F+
5 open slot for voltage measurement
wago#3
1 - from driver output#1
2 to cob A -
3 to cob B -
4 to cob C-
5 to wago #4
wago #4
1 - from wago #3
2 to cob D -
3 to cob E -
4 to cob F-
5 open slot for voltage measurement
wago#5
1 + from driver output#2
2 to cob G +
3 to cob H +
4 to cob I+
5 to wago #6
wago #6
1 + from wago #5
2 to cob J +
3 to cob K +
4 to cob L+
5 open slot for voltage measurement
wago#7
1 - from driver output#2
2 to cob G -
3 to cob H -
4 to cob I-
5 to wago #8
wago #8
1 - from wago #7
2 to cob J -
3 to cob K -
4 to cob L-
5 open slot for voltage measurement
It will get very complicated and with too many wire through fixture.
Wago#1
1 + from driver output#1
2 + from driver output#2
3 wire to bar A as +(call it a)
4 wire to bar B as +(call it b)
5 wire to bar C as +(call it c)
Wago#2
1 + wire from wago#1 (wire a)
2 + to cob 1a(first cob of bar A)
3 + to cob 2a(second cob of bar A)
4 + to cob 3a(third cob of bar A)
5 + to cob 4a(fourth cob of bar A)
Wago#3
1 + from wago#1 (wire b)
2 + to cob 1b (first cob of bar B)
3 + to cob 2b (second cob of bar B)
4 + to cob 3b (third cob of bar B)
5 + to cob 4b ( fourth cob of bar B)
Wago#4
1 + from wago#1(wire c)
2 + to cob 1c (first cob of bar C)
3 + to cob 2c (second cob of bar C)
4 + to cob 3c (third cob of bar C)
5 + to cob 4c (fourth cob at bar C)
Do the same for -
Using 3 junction box (1 for each bar).
Central bar will have junction box with:
wago#1(to split + from driver in 3) wago#2 (to split + between its 4 cob)
Wago 1bis (configured as wago#1 but for -)
Wago 2bis (configured as wago#2 for -)
Than each pair from wago#1 and wago#1bis will go to Junction box of bar B and bar C.It should be more clean configuration, with 3 box and just few wire connecting junction box between them.Is this ok?