@bobthebricklayer
Member
You would increase the air exchange by adding a bigger exhaust fan rather than adding an intake fan. Passive intake is fine. What size tent do you have? And what kind of 4" exhaust fan are you using? When you say inline fan it's not just one of those duct fans is it?
If the RH is 60 in the room the tent is in you should be able to keep it close to that. It shouldn't spike that much in the tent. Something with your setup is incorrect.
The tent with the problem is just a 2’x4’ and it’s a 4” AC infinity inline fan. One major setup issue I just corrected was venting it outside before I just had it venting back into the room which was too humid to begin with I just hadn’t had time to vent it outside but now that’s done plus putting in a whole room dehumidifier has brought the room down to 45%-50% and the tent to 55%-60%