There are losses in the driver. You will always be pulling more watts input then output. It's the efficiency of the driver.Running 6 cxa3070s on a HLG-240H-42B without a dimmer.
I measured a Vf of 35.6V and at the Killawatt I draw 234W.
I thought 35.6V x 5.72A was supposed to equal 203.6W
I am glad I am getting the extra watts to cobs, but confused about the reason they are.
Is thee more efficiency related losses the farther away from the max V of the driver?There are losses in the driver. You will always be pulling more watts input then output. It's the efficiency of the driver.
Not happy with my light and want to remake it.
Working with a 23x48 tent.
I shaved an inch off to get it into my closet.
Currently running (6)cxa3070s AB, and I am going to add either (2 or 4) cxb3070s 3500K BB.
One HLG-240H-42B right now and another on the way.
I want help designing a fixture that offers better spread and is just plain better that what Im running
I am running 5.7A divided up, so right now like 950mA each I thinkWhat current were you running for your CXA's?
I too just picked up a 4x2 tent....set it up last night actually...1st tent. I am aiming for around 15-17 Par watts/ per sq ft....probably somewhere around 800-850ppfd overall....the last nine months of 750-ish ppfd is producing over 1gm/watt....
I too am going for a couple of the those 3500KK BB 3070's....but I also have my usual mish mash to go with them as well....
I have
2x CXA 3070 AB's 3k
1x Vero 29 3k Vs. 1
1x Vero 29 4k Vs. 2
8-9x Vero 10 3500K
2x 2700k Vero 13
4x XpE 730nm
630 nm Osram's
I am pulling 234 at the wall right nowI am running 5.7A divided up, so right now like 950mA each I think
Is it wired #1, #2...instead of #1 and #3 terminals, sounds like the wiper is grounded.I bought 10pack of pots, either I am stupid or they are all broken.
Turn dial and light goes up and down and flickers.
I tried to measure resistance with fluke ad the resistance is bouncing allover the place
I have no idea how to connect it, have 10 of them, and they all act the same.Is it wired #1, #2...instead of #1 and #3 terminals, sounds like the wiper is grounded.
I have no idea how to connect it, have 10 of them, and they all act the same.
Tech on phone at mean well said just connect any 2 and no need to use the 3rd.
Doesnt sound right to me, but hes the tech..
one dmm says they are completely open other reading bounces all over.Try your two outer terminals and leave the middle one alone...See what happens> I bet it works.....
Hlg 185 c 1050 a with 4 Vero 18s and 2 Vero 29s puts you at almost max on the driver and almost max on the driver as well, all on nominal current or less.There are no good combinations for 3 or 4 2.1 amps from the HLG series drivers. You could run 1 each on LPC-100. 2 would fit on a HLG-185H-C2100 except there's no such thing.
When HLG-240H-C1750 is available it will run 3, but 1.75 amps not 2.1.
Vero just isn't HLG friendly.