UnpossibleOne
Member
Hi all,
It looks like my original post got goobered, so I'll take a do-over with upgrades to my original proposal. What I am looking straight down the barrel of now is setting up a small grow room, and an adjacent bloom room. I'll lay out my plans first, and welcome any advice or input from the BTDT crew while I am still scribbling notes & roughing it in...
The grow room is 72"L x 42"W x 86"H, and the bloom room is slightly larger at 72"L x 66"W x 96"H. These are sited in an unfinished residential basement, which gets very little use, mostly to store our swimming pool and partio junk over winter.
Both rooms will be lit by air-cooled 1000 watt vapor lamps, each pulling fresh 65°F air from one common 20"x20" filtered grate inlet, through 8" insulated flex-ducts, and exhausting into the house HVAC air return duct. Each lamp will have it's own cooling air ducts, and will run on 240V AC.
Both rooms will have their own independant CO2 enrichment systems, circulation fans, and basic environmental monitoring systems (timers, min/max thermometers, hygrometers, automatic fire extinguishers.) Each room will have it's own 15 amp 120V circuit, but will share one 40 amp 240V circuit for both large lights. All the wiring will be encased in conduit, and securely fixed to the walls.
Outside of and within a shared block wall, is a 6" masonry flue inlet. (Pre-central heat & air, we used to heat with a 48" log & #2 oil furnace, this is it's exhaust) My plan is to have one 6" fan here, tee'd to more flex-duct and a 6" charcoal filter inside each room... so that one fan purges both rooms through filters and "up the chimney."
One 'assumption' that I'm gambling on is that my HVAC return will create enough suction to draw fresh cool air through the 20" x 20" filter, past the lights and into the HVAC air handler. We spec'd the hardware a bit larger than required forecasting an additional 10x20 room, so my guess is yes? Guesstimated duct runs are 12' for the bloom room and a bit less, maybe 10' for the grow room. I can get a pair of additional inline fans, but would like trying to use this 'free' air if it's do-able. This, and my hack labor might be the ONLY thing free about this project.
How is this all sounding so far? And thanks for any creative or thoughtful insight! I'm positive I have overlooked something...
It looks like my original post got goobered, so I'll take a do-over with upgrades to my original proposal. What I am looking straight down the barrel of now is setting up a small grow room, and an adjacent bloom room. I'll lay out my plans first, and welcome any advice or input from the BTDT crew while I am still scribbling notes & roughing it in...
The grow room is 72"L x 42"W x 86"H, and the bloom room is slightly larger at 72"L x 66"W x 96"H. These are sited in an unfinished residential basement, which gets very little use, mostly to store our swimming pool and partio junk over winter.
Both rooms will be lit by air-cooled 1000 watt vapor lamps, each pulling fresh 65°F air from one common 20"x20" filtered grate inlet, through 8" insulated flex-ducts, and exhausting into the house HVAC air return duct. Each lamp will have it's own cooling air ducts, and will run on 240V AC.
Both rooms will have their own independant CO2 enrichment systems, circulation fans, and basic environmental monitoring systems (timers, min/max thermometers, hygrometers, automatic fire extinguishers.) Each room will have it's own 15 amp 120V circuit, but will share one 40 amp 240V circuit for both large lights. All the wiring will be encased in conduit, and securely fixed to the walls.
Outside of and within a shared block wall, is a 6" masonry flue inlet. (Pre-central heat & air, we used to heat with a 48" log & #2 oil furnace, this is it's exhaust) My plan is to have one 6" fan here, tee'd to more flex-duct and a 6" charcoal filter inside each room... so that one fan purges both rooms through filters and "up the chimney."
One 'assumption' that I'm gambling on is that my HVAC return will create enough suction to draw fresh cool air through the 20" x 20" filter, past the lights and into the HVAC air handler. We spec'd the hardware a bit larger than required forecasting an additional 10x20 room, so my guess is yes? Guesstimated duct runs are 12' for the bloom room and a bit less, maybe 10' for the grow room. I can get a pair of additional inline fans, but would like trying to use this 'free' air if it's do-able. This, and my hack labor might be the ONLY thing free about this project.
How is this all sounding so far? And thanks for any creative or thoughtful insight! I'm positive I have overlooked something...