12x Bridgelux EB Gen 2 Build help

benjamm1n

Member
I am planning on building an Led array using 12 Bridgelux EB Gen 2 strips (BXEB-L1120Z-35E4000-C-B3).
I would wire split them into groups of 3, wiring them in parallel and then wiring the 4 of them in series.
The driver used will be a Meanwell HLG-480H-C2800B.
This would give each strip 39v and 1050mA if my calculations are correct.
Am I missing something ?
photo_2023-03-01_22-12-18.jpgDiagramm of the wiring:
 

benjamm1n

Member
Just tested the setup using the Continuity setting on my multimeter which shows that all strips can be reached from the point where my driver will be connected. But when connecting the driver with or without dimmer on 100 % nothing happens. What could be the issue ?
Sorry if this might be a bit vague.
 

cobshopgrow

Well-Known Member
check your wiring.
your shematic is very hard to read btw, i havent digged in to it.
its not that hard normally, but seems you should check your sereis and parallel wiring.

connect 3 groups each plus and minus connected an then connect these in series.
but its normally a bit less wiring do it the other way around anyway.
connect 4 strips in series an then these 3 groups in parallel to your driver.
while both should work.
 

shimbob

Well-Known Member
I think I've deciphered your diagram and it's not right. It looks like you've got all 4 groups of 3P strips all in parallel with each other, but you've flipped the polarity of group 2 and 4.
Is the wiring you have now shown on the top row of my picture?
IMG_20230301_221811.jpg

What you describe is the middle row, and as cobshopgrow mentions, the alternative wiring on the bottom row
 

shimbob

Well-Known Member
Ignoring the wiring fault in your new diagram, wiring those strips as 4P3S is worst than your original 3P4S plan as you're now leaving about 109W unused due to poorly matched voltages.
 