    DIY COB Build Electrical Safety Concerns

    Thank you so much @CobKits , seems like problem solved. I'll install fused IEC connectors with a 4A fuse per fixture and should feel safe i guess.
  2. T

    DIY COB Build Electrical Safety Concerns

    What a great idea to check the datasheet, @230V the driver draws 1A, so i should be looking for a 1100mA fuse now i guess?
  3. T

    DIY COB Build Electrical Safety Concerns

    @VegasWinner Looked these things up already, seems like a great thing, well adaptable to a build but would 10A be right for my setup? I'll have 200w clu048 1212 lamps, each with a 10A fuse and I'm good?
  4. T

    DIY COB Build Electrical Safety Concerns

    So if a meanwell hlg 185h c1400b driver puts out 1.4A, it also draws 1.4A? And a 2A fuse would be adequate? Timber has 10A fuses installed i think. So again I'm a little confused.
  5. T

    DIY COB Build Electrical Safety Concerns

    Hello all! Planning my first LED build and since I´m quite paranoid about electricity, have come up with a few questions. Most builds don´t seem to mention adding a fuse to the input side of the driver, but for instance Timber has one installed. It would seem easier for me to install a circuit...