no, and i dont run pump filters.does nay1 get issues with the organic nutes clogging the ez clone misters??
in terms of the spray manifold, talk me a bit more about what you did to drill the holes in the end caps and wat part you used to connect the out side to the inside.. how were you able to figure out the exact location to make the hole on the endcap??here is the 50gal, 3 rail, 12 site system. i have 3 of these and harvest 1 every 3 weeks. when completely assembled the manifold is secured and leak proof, just so no one points that out. this system has had 11-12 harvests and never replaced a part or had a leak. i just noticed in the pics the center rail and the rail on the right should be switched and the stagger pattern is more identifiable.
i used a combination on those manifolds. the end covers are made from a piece of the fence post, the barbed connectors are from landscape irrigation section at lowes, and used the grey plumbing fixtures on inside of cap(1/2" thread to slip). barb fitting screws through cap into grey fiiting, sprayer rails slips into grey fitting inside. main reason i used 2 offset 45* elbows is to let me have adjustments to get sprayer bar to corner.in terms of the spray manifold, talk me a bit more about what you did to drill the holes in the end caps and wat part you used to connect the out side to the inside.. how were you able to figure out the exact location to make the hole on the endcap??
flower is 12/12, veg is 24/0.Hi StinkBud and all, What is your lighting set for in the flower room 12/12?
3/4" for frame. dremel tool, gotta love it. assemble the frame and put rails on, assemble the drain and sit in drain hole. slide rails to where bottom edge contacts drain and mark. use a long straight edge and extend it along drain so all holes are even on bottem cut. then cut up and over to complete, may have to test fit a little. leave enough room on top cut for rail end piece(manifold) slides down in a little. on the bottom of rails i cut and bent a drip edge to prevent drops walking back up the rail and to lock rail into drain.SS for the the support rail system for the posts ( flowering system) are you using 3/4 PVC or 1" PVC?
Also in the 2 Inch drain pipe, How did you cut rectangles in the pipe and made sure they fit well??
SS, found some of your posts and photos, nice set up. I will keep searching your post. Thank you
How long are the PVC 3/4 going across?they are 45* elbows, it lets rail sit to edge of rail
middle to cool res more even. the extensions are no biggie, my others i cut and rebent but forgot to on this one.
drain and t are 2"
between rails is 8" between plants is 12"
rails come 96", i cut to 46"
frame sits about 1/4" above res.
Are you talking about the new one in his new book?Also is there any diagrams of StinkBud's single system posted anywhere?