Yea I’m working on getting one. What cfm rating do you think would be sufficient for this size tent?
That depends on what your ambient temps are, say if your room is 70 degrees and you want the tent 80 then obviously it takes less cfm than it would if your room was 78 degrees and you wanted 80.
The calculation for that is
CFM = 3.16 x Watts / DT(°F)
Watts is the lighting power (and any other 'hot' things in the grow space) in Watts.
DT is the allowable temperature rise within the enclosure (i.e. desired temperature minus ambient temperature) in °F.
So, to work out the size of fan required (in CFM) simply plug your lighting Wattage into the equation along with the DT value.
An example is:
Ambient temperature = 20 °C
Target temperature of the enclosure = 25 °C
DT in °C = 25 - 20 = 5
DT in °F = 5 x (9 / 5) = 9
Lighting Wattage = 250 Watts
Plugging these values into the equation gives:
CFM = 3.16 x 250 / 9 = 87.77