booms111
Well-Known Member
I'd like to see the uMols for the areas I circled in red and how 2 lights running at 100w would compare to your graphs. Id assume that all light sources(hps,cob,qb,strips) graphs would look different from each other with cobs being one of the most beneficial lights to run more of a group with the lower amount of spread they have compared to say a hps with a hood. Thanks for graphs and info.I dispelled this myth recently:
This is what you get with a single 200W light source
View attachment 4125362
The 1000 to 500 uMol zone is 12" deep.
Here is what four 50W light sources looks like:
View attachment 4125368
You'll notice that while you still have 250 uMol at the floor, the 1000 to 500 uMol zone is higher and stretched out. the "zone" is closer to 18" in depth.
Lets see what eight looks like:
View attachment 4125374
As you can see - the floor is still at 250 uMols, and the "zone" is stretched to about 21".
In reality, penetration is not about having a high initial intensity single light source - its about how many PAR watts you're putting in and how uniform you can spread those photons.