nachoo you are on the right track. Here are some other pieces of info you might find helpful.
1 DLI = 278 PPFD for 1 hour. For example, 10 hours @ 278 PPFD will give you 10 DLI whereas 10 hours of 550 PPFD will give you 20 DLI.
You can manipulate the DLI via time and light output. The magic number however is what the plant will take in, usually somewhere between 10-65 DLI. To make it even more complicated the light requirements are different for each stage of growth. Most people use a slow growth veg method whereas I am now leaning towards a higher DLI once the plants have reached a size that covers the light footprint. Prior to flip they will be at the same DLI going into flower and it seems to help with the transition.
I use GLR in veg since I have the light power and don't need to run 12 hrs per light cycle. To do 10/14 for example, 4 on, 5 off, 1 on, 5 off, 5 on, 4 off. You actually want to avoid FR in veg since it is the signal to sleep. Has little impact as DLI is king at this stage.
Most important in all of this is keeping temps down using good air circulation. I have run plants under 3500 PPFD with good temp control and didn't get any increase in yields over <1000 for the same 12/12 cycle. Lettuce can handle 5000 PPFD but it doesn't grow more. Good air circ also removes the need for CO2. In my opinion having to add additional CO2 just means that there isn't enough airflow so kill two birds with one stone. Hyper efficient LEDs let you keep ambient temps well within the 20-30c range which is optimal. Soon we will be spending more of our electricity on fans than lights.
And mag isn't a problem, more like dealing with symptoms and not a fix. The problem is the plant running out of mag to handle the excess light the cells are receiving. If you get your lighting dialed into the proper DLI that the plant wants then you won't have the issue.
I have been thinking...as the goal is reduce flowering times...maintaining same production and electricity cost..
If a 8/16 is done aumenting the PPFD adding about 33% more PPFD that in a 12/12 , then we got lesser flowering times due to very longer nights..with same DLI.
But adding far red treatment at the end of this 8 hours..is like 8/18...so more longer night....less flowering times again
At this point I would be using a DLI of about 38,5 about 1300 PPFD the 8 hours of light , before I was using same DLI with 1000 PPFD in 12 hours.
As Photon Flinger wrote the plant can take 10-65 DLI..DLI is refered to a 24 hours period if I understand well...
So we have a 8/16 timing that with far red is like 8/18...a day of 26 hours (indoor conditions)
Could be possible (maintaining the far red)... to use artificial days of less than 24 hours to reduce even more the flowering period? I mean like 8/10 day with far red will be like a 8/12..so flowering is possible... I understand that this is a lot of work with timers...sorry if you cant follow my logic cause english is not my native language
Could be this go further using a 6/10 with far red (6/12)? ..Instead of 24 hours day, 16 hours days... only 6 hours of light with high PPFD(about 1600), lot of ventilation and magnesium...Will it be possible? or I am thinking too much
. A plant in a 16 hours day should accept 7-44 DLI?