DrKran
Active Member
Hi guys. I finally finished my Vent project in the grow room. I was at it all day on Friday.
Basically the task was to install 2 inline fans (1 for the closet, to take the air out of the room & and 1 to take the hot air from the reflector). I also set out to get the intake air directly to the plants instead of the top of the room. This way all my temps should get much better.
First some room pics pre work.
The Inlines:
2 S&P TD series Inline fans + ducting = $501
The S&P TD500 has a 350 CFM and was installed for the Reflector (it should be work fine with a 1k lamp but ill get that on Monday).
This is all I have for now.
The S&P TD350 has a 200 CFM and was installed on the Closet. Both fans will take hot air trough the top of the room.
First I wanted to get the air from that top intake fan to go straight to the plants adding a box and ducting.
Intake to the Grow Room.
It went from this:
To this:
Right into the main grow area.
The Inlines: I needed 2 big holes for the ducting on the 8 inches concrete roof so i got some Local Help for just $35 in 3 hours.
The result:
Now the fans and ducting:
Fans ON!
I used foamed up to prevent air, ligh or water leaks.
The Inline for the closet:
Now for the reflector:
Horizontal full view:
Now with the Ladies:
http://www.420magazine.com/gallery/data/1157/medium/BB_CC_Agst_29_079.jpg
Also added some fans and diff spectrum on some CFL. Ill switch the rest when I find something more than 24wtts.
That's it. I'm very very happy with the results. Ill do a follow up on the temps before and after. On Monday Ill try the 1K HPS and check temps again.
Tomorrow Ill Post a follow up on the Mothers growing in the closet.
Basically the task was to install 2 inline fans (1 for the closet, to take the air out of the room & and 1 to take the hot air from the reflector). I also set out to get the intake air directly to the plants instead of the top of the room. This way all my temps should get much better.
First some room pics pre work.
The Inlines:
2 S&P TD series Inline fans + ducting = $501
The S&P TD500 has a 350 CFM and was installed for the Reflector (it should be work fine with a 1k lamp but ill get that on Monday).
This is all I have for now.
The S&P TD350 has a 200 CFM and was installed on the Closet. Both fans will take hot air trough the top of the room.
First I wanted to get the air from that top intake fan to go straight to the plants adding a box and ducting.
Intake to the Grow Room.
It went from this:
To this:
Right into the main grow area.
The Inlines: I needed 2 big holes for the ducting on the 8 inches concrete roof so i got some Local Help for just $35 in 3 hours.
The result:
Now the fans and ducting:
Fans ON!
I used foamed up to prevent air, ligh or water leaks.
The Inline for the closet:
Now for the reflector:
Horizontal full view:
Now with the Ladies:
http://www.420magazine.com/gallery/data/1157/medium/BB_CC_Agst_29_079.jpg
Also added some fans and diff spectrum on some CFL. Ill switch the rest when I find something more than 24wtts.
That's it. I'm very very happy with the results. Ill do a follow up on the temps before and after. On Monday Ill try the 1K HPS and check temps again.
Tomorrow Ill Post a follow up on the Mothers growing in the closet.