Thanks goes to Cali Worthington for finding those Prolimatechs, a great choice. You found some that are illuminated?
As far as the size of the fans 140mm fits perfectly on the 5.88" Heatsink USA profile, so that the air blows down the the channel between every fin. That is the most efficient way to make use your heatsink and your fan power. You could add a shroud to cover the channels but the air blows all the way down CWs 24" heatsink channels (9" travel distance) with no problem. (Fans at 13V)
If you have the design flexibility for remote drivers, I highly recommend it. If you install the drivers on the heatsink you would be pumping some of that heat back into the heatsink and COBs, sabotaging your Tj to some extent. Also it is more heat in the grow space, increasing canopy temps. For a 230 dissipation W build with 2 fans, input power is about 270W. So the drivers are dissipating about 35W of heat.
Using remote drivers increases the wiring running through your grow space, so to keep it neat we have been using 18/6 stranded alarm cable.