• Here is a link to the full explanation: https://rollitup.org/t/welcome-back-did-you-try-turning-it-off-and-on-again.1104810/

Exhaust Rate?

What kind of air turnover rate should I aim for in my grow? I will be growing DWC in a 12x15 space, with veg taking up 5x12 and flower with 4 SCROGs in a 10x12 space. There will be a divider running between them and fresh air will enter in the veg, then be vented into the flower room.

Basically I have a room that is divided, but 960 cu ft overall and I want to purchase an appropriately sized exhaust fan and carbon filter.
 

anzohaze

Well-Known Member
Air exchange every 3 minutes is typical so round off to 1000 cubic ft divide by 3 would be 333 cfm always go a little bigger esp w going vetween 2 rooms I would suggeat 400-500 cfm or if 2 fans do 250cfm a peice. For a filter you want to do every 3.mi utes as well I always do more for air cleanliness. I have a 8x39 phresh inch filter with I think 700 cfm filter rated at 850, I have a 6x24 phresh filter with a 400 on it and filter is 450 cfmmi think both filter are in my 87psqft room so I have way over kill but absolutely no smells
 
Last edited:

SnapsProvolone

Well-Known Member
Preheating the intake by rumning it through veg before flower is not wise.

Eah area should have it's own intake, exhaust and environmental controller.
 
Top